Non-contact temperature measurement• ±0.5℃ high precision temperature measurement without external black body
• Array uniformity of temperature measurement: ≤±0.3℃ -
Fast integration into system• An all-in-one standard Type-C interface with power supply, data transmission and control
• Support Windows/Android/Linux SDK; achieve video stream analysis, module control, comprehensive array temperature measurement, temperature imaging, temperature window setting and multi-unit integration
TEMP317 infrared camera core is specially developed for epidemic prevention and medical diagnosis. It is integrated with self-developed wafer level package 384×288/17μm infrared detector and temperature measurement SDK with accuracy up to ±0.5℃.
It is a kind of infrared product for fever detection and temperature screening that uses image analysis software to detect and mark the areas of an image where a defined temperature threshold has been exceeded. If the software detects that this temperature threshold has been exceeded in a person’s thermal image, this indicates the probability that this person has an elevated body temperature. The captured temperature data and heat distribution of target can be used to achieve radiation-free, non-invasive early disease diagnosis and long-distance, large-scale body temperature screening.
There are two modes of temperature measurement distance which can be used in various scenarios. The TEMP317 infrared camera core has a better temperature measurement consistency and superior temperature measurement accuracy of ±0.5°C. No need for built-in black body ensures a compact design and easier temperature measurement. Without external black body, the TEMP317 infrared camera core has a compact & light structure, which guarantees a lower integration cost. It has an all-in-one standard Type-C interface with power supply, data transmission and control, customers can quickly develop and integrate various temperature measuring systems like medical diagnosis and epidemic prevention.
The TEMP317 infrared camera core can be quickly integrated into various medical thermal imaging devices, and it is expected to be widely used in the fields of Disease Screening, Traditional Chinese Medicine Physiotherapy, Health Check-up, Rehabilitation etc. at present and in the future.
Model | TEM317 |
Infrared Detector | VOx (Wafer-Level-Package) |
Resolution | 384×288 |
Pixel Size | 17μm |
Spectral Response | 8~14μm |
Typical NETD | <50mK |
Frame Rate | 25HZ |
Start-up Time | 5s |
Digital Video | RAW/YUV |
Communication | USB2.0 |
Image Algorithm | NUC/3DNR/DNS/DRC/EE/SFFC |
Working Voltage | 5±0.5V |
Typical Power Consumption | 0.85W |
Working Temperature | -10℃~+50℃ |
Temperature Measurement Range | 15℃~50℃ |
Temperature Measurement Accuracy | ±0.5 ℃ after 2 minutes of startup (Target temperature range is 32℃~42℃, and ambient temperature is 23±3 ℃) |
Measuring Distance | ① 0.5m (Depth of field is 0.4m~0.6m) ② 0.8m and 2m (The distance is switched through software or serial command. Depth of field is 0.8m~∞ m) |
Size (mm) | ≤25.4×25.4×37.7 (With 7mm Lens) ≤25.4×25.4×37.7 (With 9.1mm Lens) |
Weight | 38.5±3g (With 7mm Lens) 38±3g (With 9.1mm Lens) |
Lens | Fixed Focus Athermal: 7mm/9.1mm |
Array Uniformity | ≤±0.3℃ |